Description

The PROFI-5018 is specially designed for the slave device of PROFIBUS DP protocol. It supports up to 10-channel Thermocouple Input Module with High Voltage Protection. Users can easily to choose and configure it by using the GSD file in any PROFIBUS Configurator.

Features

  • Protocol & Hierarchy : DP-V0 Slave
  • Transmission Rate Setting : detected automatically
  • Address Setting : Address 0~126 set by rotary switches or SSA Telegram
  • I/O modules Configuration : Configured by GSD file
  • Network Isolation Protection : High Speed iCoupler
  • 4KV ESD Protection : Contact for each terminal

Specifications

CPU Module
CPU 80186, 80 MHz or compatible
EEPROM 2 KB
Flash 512 KB
SRAM 512 KB
Watchdog Timer Watchdog IC
CPU built-in
LED Indicators
Status PWR LED, RUN LED, ERR LED
Analog Input
Channels 10 channel differential thermocouple input, Isolation Voltage:2500Vrms
Range +/-15mV, +/-50mV, +/-100mV, +/-500mV, +/-1V, +/-2.5V, +/-20mA, 0~20mA, 4~20mA
(requires optional external 125 Ohms resistor), Thermocouple Type: J, K, T, E, R, S, B, N, C
Accuracy +/- 0.1 of FSR
PROFIBUS
Controller Siemens SPC3
Transceiver DI ADM2486
Baud Rate 9.6 k, 19.2 k, 45.45 k, 93.75 k, 187.5 k, 500 k, 1.5 M, 3 M, 6 M, 12 M
Isolation 3000 VDC for DC-to-DC, 2500 Vrms for bus-to-logic
Protocol DP-V0
Power
Consumption 3.5 W
Mechanical
Dimensions (mm) 91 x 130 x 52 (W x L x H)
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75℃
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing

 

Applications

  • Industrial Automation
  • Factory Automation
  • Process Automation

Description

The PROFI-5018 is specially designed for the slave device of PROFIBUS DP protocol. It supports up to 10-channel Thermocouple Input Module with High Voltage Protection. Users can easily to choose and configure it by using the GSD file in any PROFIBUS Configurator.

Features

Specifications

CPU Module
CPU 80186, 80 MHz or compatible
EEPROM 2 KB
Flash 512 KB
SRAM 512 KB
Watchdog Timer Watchdog IC
CPU built-in
LED Indicators
Status PWR LED, RUN LED, ERR LED
Analog Input
Channels 10 channel differential thermocouple input, Isolation Voltage:2500Vrms
Range +/-15mV, +/-50mV, +/-100mV, +/-500mV, +/-1V, +/-2.5V, +/-20mA, 0~20mA, 4~20mA
(requires optional external 125 Ohms resistor), Thermocouple Type: J, K, T, E, R, S, B, N, C
Accuracy +/- 0.1 of FSR
PROFIBUS
Controller Siemens SPC3
Transceiver DI ADM2486
Baud Rate 9.6 k, 19.2 k, 45.45 k, 93.75 k, 187.5 k, 500 k, 1.5 M, 3 M, 6 M, 12 M
Isolation 3000 VDC for DC-to-DC, 2500 Vrms for bus-to-logic
Protocol DP-V0
Power
Consumption 3.5 W
Mechanical
Dimensions (mm) 91 x 130 x 52 (W x L x H)
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75℃
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing

 